Airmar PB200 Technical Information

Stöbern Sie online oder laden Sie Technical Information nach Wetterstationen Airmar PB200 herunter. Airmar PB200 Technical information Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 28
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Record the serial number found on the
WeatherStation® instrument.
Serial No._________________________
Date of Purchase___________________
17-461-01 r01 01/01/08
WeatherStation
®
Instrument
Owner’s Guide
Model PB200
Seitenansicht 0
1 2 3 4 5 6 ... 27 28

Inhaltsverzeichnis

Seite 1 - Instrument

Record the serial number found on the WeatherStation® instrument.Serial No._________________________Date of Purchase___________________17-461-01 r01 0

Seite 2

10InstallingWARNING: Always wear safety goggles and a dust mask.CAUTION: The blue metal plate and the blue film found in the wind channel of the Weath

Seite 3

11WARNING: Always wear safety goggles and a dust mask.1. Place the antenna mount at the selected location and mark the holes for the screws (see Figur

Seite 4 - Introduction

126. With the nut assembly on the cable near the WeatherStation connector, thread the cable through the extension tube (if used), antenna mount, and t

Seite 5 - Safety Instructions

13Cable Routing & Connecting GuidelinesYou must read the safety instructions below before going to the section that is appropriate for your equipm

Seite 6

14Connecting to an NMEA 0183 Display1. Route the WeatherStation cable to the display. Do not fasten the cable in place at this time.2. Connect the Wea

Seite 7 - Parts, Tools & Materials

157. Your installation is complete. To begin receiving weather readings, refer to the owner’s manual that came with your display. Figure 6. Wiring dia

Seite 8 - Where to Purchase Parts

16Connecting to an NMEA 2000® NetworkCAUTION: Only two termination resistors are required on an NMEA 2000 network. More than two will degrade the bus

Seite 9

17Calibrating the CompassThe internal compass must be calibrated for accurate compass readings. To calibrate the compass, use the WeatherCaster™ softw

Seite 10 - Installing

18Where to Purchase PartsObtain parts from your marine dealer.Gemeco Tel: 843.394.3565(USA) Fax: 843.394.3736Email: [email protected] EMEA Tel:

Seite 11

19NMEA 0183 Combiner ProblemsThe LED light on the Combiner indicates its current operating mode and if an error is detected during the self-test proce

Seite 12

Copyright © 2008 Airmar Technology Corp. All rights reserved.

Seite 13

20Appendix A—How the WeatherStation Instrument WorksAbout the Ultrasonic Wind SensorThe ultrasonic wind sensor (an ultrasonic anemometer) measures app

Seite 14 - No Connector—Wiring

21Consider the case of a vessel proceeding at a speed of 15 knots in calm air. An observer on board would experience a wind of 15 knots from dead ahea

Seite 15 - NMEA 0183 display

22About the Electronic CompassThe WeatherStation instrument includes three magnetoinductive sensors that measure magnetic field-strength in three axes

Seite 16 - Network

23The WeatherStation instrument calculates two values for wind-chill temperature: one using the apparent wind-speed, and one using the true wind-speed

Seite 17 - Software

24optional Combiner), in order to enable the true wind capabilities of the WeatherStation instrument.Even if your WeatherStation instrument includes a

Seite 18 - Troubleshooting

25Appendix B—Technical InformationNMEA 0183 Sentence Commands* These sentences are enabled at the factory. $GPDTM Datum Reference$GPGGA * GPS Fix Data

Seite 19 - PC Problems

26PGN 126720-33 Proprietary: Calibrate CompassPGN 126720-34 Proprietary: True Wind OptionsPGN 126720-35 Proprietary: Simulate ModePGN 126720-49 Se

Seite 20 - 4 transducers

27transmitted are, nevertheless, retained in the WeatherStation instrument. For more detailed information, see the “Technical Manual” on the WeatherSt

Seite 21

2835 Meadowbrook Drive, Milford, New Hampshire 03055-4613, USA www.airmar.com

Seite 22 - About Wind Chill Temperature

3Table of ContentsIntroduction...4Safety Instructions...

Seite 23 - About the GPS

4IntroductionThank you for purchasing the Airmar ultrasonic WeatherStation instrument. This exciting product is actually six different sensors in a si

Seite 24

5Safety InstructionsWARNING: Electrical SafetyThe power supply voltage must be 12 VDC (±3VDC). Any other voltage may damage the product and/or result

Seite 25 - Transmitted NMEA 2000® PGNs

6The Importance of Understanding True Wind DirectionWhen the WeatherStation instrument is stationary, the direction from which the wind is blowing is

Seite 26 - Received NMEA 2000® PGNs

7Parts, Tools & MaterialsCables, Converting, and Connecting HardwareThe WeatherStation instrument can be connected to a device and/or network in s

Seite 27

8Additional Tools and MaterialsSafety gogglesDust maskPencilLevelElectric drillDrill bitsDeck gland (some installations)Phillips screwdriversPlumber’s

Seite 28

9Choosing the Mounting LocationFor accurate readings and a reliable GPS signal, selecting the best location for the WeatherStation instrument is very

Kommentare zu diesen Handbüchern