17-444-01 rev. 03 12/14/10
Analog to NMEA 0183 Format
Data Converter
for Speed and/or Temperature Data
Parts
Gemeco Tel: 803-693-0777
(USA) Fax: 803-693-0477
Airmar EMEA Tel: +33.(0)2.23.52.06.48
(Europe, Middle East, Africa) Fax: +33.(0)2.23.52.06.49
Copyright © 2007 Airmar Technology Corp.
Figure 1. Connecting (not to scale) (CS4500 installation shown)
Application
To convert analog speed and temperature data to NMEA 0183
digital format.
Guidelines
CAUTION: To reduce electrical interference from other electrical
wiring and any on-board equipment with strong magnetic fields such
as radar equipment, radio transmitters, boat engines, generators,
etc., separate the cables by at least 1m (3').
CAUTION: Be careful not to tear the cable jackets when passing
them through the bulkhead(s) and other parts of the boat. Use
grommet(s) to prevent chafing.
CAUTION: Make power connections to a 12 VDC power source
that is isolated from the engine start battery(s). Voltage drops may
cause the instrument/receiver/sensor to lose information and/or
change operating mode.
CAUTION: Use a multimeter to check the polarity and the con-
nections to the power supply before applying power to the sensor.
Tools & Materials
Safety goggles
Dust mask
Pencil
Grommet(s) (some installations)
Cutting pliers
Phillips screwdrivers
speed & temperature
sensor
power
12 VDC
1
2
3
4
5
6
7
8
Data Converter
display
sensor/instrument cableData Converter cable
Black 12 VDC –
Red 12 VDC +
White NMEA A/+
Blue NMEA B/–
Bare Shield
Wire Function
Color
terminal
block
temp
5V out
ground
signal in
temp
brown
red
bare
green
white
bushing
terminal function
wire color
4
5
6
7
8
INSTALLATION INSTRUCTIONSOWNERS GUIDE &
WARNING: Always wear safety goggles and a dust
mask when installing to avoid personal injury.
WARNING: The power must be OFF before wiring if
the instrument is already connected to a power source
to avoid personal injury or death.
WARNING: The power supply voltage must be
12 VDC. Any other voltage may damage the sensor
and/or result in fire, causing damage to the boat,
personal injury, and/or death.
WARNING: A safe installation requires a 0.5 amp fast-
blow fuse or circuit breaker. Failure to do so may result
in fire, causing damage to the boat, personal injury,
and/or death.
IMPORTANT: Read the instructions completely
before proceeding with the installation. These
instructions supersede any other instructions in your
instrument manual if they differ.
Alcohol (optional)
Wire strippers
Heat-shrink tubing
Heat gun
Blade screwdrivers
Electric drill
Drill bit 3mm or 1/8"
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - Analog to NMEA 0183 Format

17-444-01 rev. 03 12/14/10Analog to NMEA 0183 Format Data Converterfor Speed and/or Temperature DataPartsGemeco Tel: 803-693-0777(US

Seite 2 - Completing the Installation

Copyright © 2006 - 2010 Airmar Technology Corp. All rights reserved. Locating the Converter1. Select a convenient dry mounting location for the water-

Kommentare zu diesen Handbüchern

Keine Kommentare