17-589-01 rev. 02 03/24/14
Applications
Keel mount in fiberglass hull only.
Keel mount recommended for high-speed boats.
Hole Saw
Hole Saw 95mm or 3-3/4”
Mounting Location
CAUTION: Do not mount in line with or near water intake or
discharge openings or behind strakes, fittings, or hull irregularities
that will disturb the water flow.
Choose a Location
In a cool well-ventilated area away from the engine to avoid
overheating.
Where the transducer will be in contact with the water at all
times.
Where the water flowing under the hull is smoothest with a
minimum of bubbles and turbulence (especially at high speeds).
Do not mount the transducer near water intake or discharge
openings; or behind strakes, fittings, or hull irregularities.
Where the transducer beam will not be blocked by the propeller
shaft(s).
Away from interference caused by power and radiation sources
such as: the propeller(s) and shaft(s), other machinery, other
echosounders, and other cables. The lower the noise level, the
higher the echosounder gain setting that can be used.
Where there is working space inside the vessel.
WARNING: The transducer must be professionally
installed using accepted practices. The pocket must be
strong and watertight to reduce the risk of property
damage, personal injury, and/or death.
INSTALLATION INSTRUCTIONSOWNER S GUIDE &
Keel Mount
Depth Transducer
Model: CM422
US Patent 7,369,458. UK 2 414 077
Record the information found on the cable tag for future reference.
Part No._________________Date___________Frequency________kHz
Follow the safety precautions below for optimal
product performance and to reduce the risk of
property damage, personal injury, and/or death.
WARNING: Always wear safety goggles and a dust
mask when installing.
WARNING: Immediately check for leaks when the
boat is placed in the water. Do not leave the boat
unchecked for more than three hours. Even a small
leak may allow considerable water to accumulate.
CAUTION: Do not install in the engine compartment or
other hot place. The transducer may fail if it overheats.
CAUTION: Always operate the transducer in water.
Operating in air will allow the transducer to overheat
resulting in failure.
CAUTION: Orient the transducer so the bosses on the
top are facing fore and aft—parallel to the centerline of
the boat.
CAUTION: The transducer must be flush with the
bottom of the hull for good performance.
CAUTION: Never pull, carry, or hold the transducer by
the cable. This may sever internal connections.
CAUTION: Never strike the transducer.
CAUTION: Never use solvents. Cleaners, fuel, sealants,
paint, and other products may contain solvents that can
damage plastic parts, especially the transducer’s face.
IMPORTANT: Please read the instructions completely
before proceeding with the installation. These
instructions supersede any other instructions in your
instrument manual if they differ.
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - Depth Transducer

17-589-01 rev. 02 03/24/14Applications• Keel mount in fiberglass hull only.• Keel mount recommended for high-speed boats.Hole SawHole Saw 95mm or 3-3/

Seite 2 - Checking for Leaks

Copyright © 2014 Airmar Technology Corporation. All rights reserved. 35 Meadowbrook Drive, Milford, New Hampshire 03055-4613, USA • www.airmar.com Boa

Kommentare zu diesen Handbüchern

Keine Kommentare