CA/CR40/42/50/52 Installation manual Chapter 11
21
11.8.4 NMEA0183 interface connections
NMEA0183 interface connections are made to the receptacle marked “NMEA1”
or “NMEA2” on the rear of the cabinet – turn the plug’s coupling ring clockwise
until it stops.
) The CA/CR40/42/50/52 must be turned off while connecting/disconnecting
the interface cable.
11.8.5 PC up/download via NMEA connection
A PC can be connected via the NMEA port to enable exchange of waypoint and
route data. See 11.10 Optional connections.
11.9 Universal connection cable
(optional)
Transducers are recommended to be 60 to 80 ohms and minimum 1kW. The uni-
versal connection cable should be applied for connecting one or two transducers
to either ECHO1 or ECHO2 port.
Pin
ECHO 1 ECHO 2
1 Red Speed log Depth 1+
2Black(brown) VCCspeed Depth1-
3 Blue Depth 1+ Depth 2+
4 Shield Shield Shield
5 White(orange) Depth 1- Depth 2-
6 Green Gnd.* Gnd. (Temp.)
7 Yellow
Temp.
*) Temp./Speed log
Temp.
Connection cable
CabletypeAMWSTYLE2464